pix Illustration pix
pix pix Home
pix
pix
pix pix Components
pix
pix
pix pix Systems
pix
pix
pix bull Software
pix
pix
pix bill SpecsLab
pix
pix bull SpecsLab Prodigy
pix
pix pix Easy Start and Operation
pix
pix pix Experiment Editor
pix
pix pix Data Views
pix
pix pix Device Controls
pix
pix pix Vacuum Control
pix
pix pix ISQAR
pix
pix pix Reporting
pix
pix pix Advanced Automation
pix
pix pix Remote In
pix
pix pix Remote Out
pix
pix pix Data Logging
pix
pix bull Download
pix
pix pix SpecsLab 2
pix
pix pix Nanonis Tramea
pix
pix pix Nanonis BP5
pix
pix pix Measurements
pix
pix pix Applications & Results
pix
pix
pix pix News
pix
pix
pix pix Downloads & Tools
pix
pix
pix pix Company Profile & Careers
pix
pix
pix pix Contact & Support
pix
pix
pix

   Your location > Software > SpecsLab > SpecsLab Prodigy > Download

Download

Download of the SpecsLab Prodigy Software Package

Usually a new minor version (4.xx.1) is released every month with bugfix updates (4.xx.yy) in between as required.

Current Version: 4.43.2-r73078
Download: SpecsLab Prodigy Installer
Password: ajmj3UCRa

Update information from recent releases:
 
=================================================
Version 4.43.1-r72916 (19-March-2018)
=================================================

Major Changes
   * Support for Windows 10 (#6846)
   * Open files in Data Browser (#6565)

Minor Changes
   * Add detector parameters to analyzer control device informations (#7174)
   * Change axis titles for Plot View and Image View Export (#7170)
   * Show image without counts as black in Image View (#7159)
   * Define Plot View and Image View size for reporting (#7148)
   * Copy spectrum without comments (#7144)
   * Improve cycle selector with respect to correlating keys (#7139)
   * Automatically reduce size of SLE files (#7104)
   * Detector calibration using a single spectrum (#7095)
   * Add option to leave device on in Devices Deactivation (#7094)
   * Improved background and peak area operations (#7028, #7027)
   * Allow saving Channel Data to sp2 in Live Image View (#6912)
   * Live Views should consider data folder from options (#6655)
   * Provide default values for missing or invalid ADC values of HSA boards (#6637)
   * Display first profiling step of 3D dataset (#6541)
   * Reporting with DocX in Plot View (#6485)
   * Disconnect devices not part of SVG in Vacuum Control (#6390)
   * Warning when Service is due in Edwards device (#5678)
   * Improved values of axes ticks in Image View (#5483)

Bugfixes
   * Faster Multi-Peak-Fit operation (#7206)
   * PicoProbe connection error (#7183)
   * VAMAS import of cycles broken (#7152)
   * BlmNSRRC does not work with constant final state mode (#7124)
   * Issues dialog does not show issues without details (#7115)
   * Importing and overwriting of analyzer breaks configuration in Configuration Tool (#7103)
   * Auto-export of spectrums inside cycles should be performed only once (#7018)
   * Exporter do not handle kinetic base energy correctly (#6622)
   * (4.43.2) Plot Definitions are not updated when data is empty (#7289)

 
=================================================
Version 4.42.0
=================================================

Major Changes
   * Support for 1D THEMIS (#6325)
  
Minor Changes
   * Add Close commands to Brooks SLA Ext and Butterfly devices (#7048)
   * Reduce decimal digits of counts and CPS in axis text (#7044)
   * Enable/Disable Devices for usage in Prodigy from configuration tool (#7040)
   * Add Pfeiffer PKR280 and others to Predefined Gauge types in VSC Gauge (#7035)
   * Device Commands PumpDown/VacControl for Vacuubrand MV10C (#7031)
   * Device commands Start/Stop for Edwards Backing Pump (#7032)
   * Device Command Open/Close for VSC Valve (#7026)
   * Allow switching Floodgun to standby in Sputter Depth Profile (#7029)
   * Logarithmic scale on y-Axes in Image View and Plot View (#6990)
   * Remove licenses for SPECS devices (#6987)
   * Enable storing values in Remote Out Device Control (#6728)
   * Allow Manual Selection of Filament in Vacom Atmion (#6727)
   * Support new Preamplifier in XRC125 (#6263)
   * Show alignment circle in Live Image View (#6261)
   * Improved display of current value in Live Data View (#6158)
   * Apply changes on multiple devices in Configuration tool (#5399)
   * Ignore auto compact mode for snapshot spectrums (#7096)
  
Bugfixes
   * Connection fails for axes with same name in manipulator device (#7086)
   * Axis text with summation are not displayed (#7014)
   * Joystick support for 64 bit systems (#7011)
   * Protocolled parameters are not always stored in Prodigy (#6836)
   * Update axis positions in manipulator device control during axis movement (#6535)
   * SpecsDevs is not shutdown properly (#6363)
   * Wrong status in MVC-3 downward compatibility for Vacuum Control (#6250)
   * Phoibos 2D ramping voltage (#7088)
   * Crashes during ramping (#7089, #7167)
   * Stack overflow when loading sle file (#7090)
   * Handle slow undulator of Beamline (#7083)
   * (4.42.2) Could not display fermi fit result correctly (#7182)
   * (4.42.2) Vacom MVC-3 / JevaMET support for firmware version 3.0 (#7178)
   * (4.42.2) Prodigy hangs after pasting multiple nodes (#7203)
   * (4.42.2) Minimum size of Periodic Library fixed (#7110)

   * (4.42.3) Crash when updating view during measurement (#7218)

   * (4.42.3) FWHM Operation calculation corrected (#7214)
 
 
=================================================
Version 4.41.0
=================================================

Major Changes
   * (none)
 
Minor Changes
   * Improved error message when validating logical voltage (#6918)
   * Update Views only when visible (#6558)
   * Added button to close all experiments in Experiment Editor toolbar (#6540)
   * Logarithmic scale on y-Axes in Live Data View and Plot View (#6310)
   * Fermi operation in Image View can be used with mirrored edges (#5659)
   * Export time stamp for each scan in xy format (#5628)
   * Allow configuration of vertical axis range in Live Data View (#4453)
   * Support new LSH with OsTech power supply (#6910)
 
Bugfixes
   * Setting pixel rate with Pixelfly USB (#6982)
   * Crashes during Multipeak Fit Operation (#6956)
 
 
=================================================
Version 4.40.0
=================================================

Major Changes
   * (none)
 
Minor Changes
   * Update CasaXPS to version 2.3.19 dev1-0m (#6422)
 
Bugfixes
   * FG 22 does not continue after setting small emission currents (#6922)
   * Wrong device status when TCP connsction ist lost (#6947)
   * Cannot open file due to wrong number of detector channels (#6975)
   * Unstable connection to SpecsDevs (#6734)
   * (4.40.2) Could not load sle file with operation on operation (#7039

 
=================================================
Version 4.39.0
=================================================

Major Changes
   * (none)
 
Minor Changes
   * (none)
 
Bugfixes
   * Crashes during anode profiling with XRC125MF (#6852)
   * Voltage sliders are not activated after switching lens mode (#6850)
   * Could not set up Phoibos parameters (#6849)
   * Ramp timer is not reset on error in analyzer control device (#6813)
   * Deadlock when validating second scan with Remote In (#6791)
   * Crashes when removing items from Live Data View (#6908)
 
 
=================================================
Version 4.38.0
=================================================

Major Changes
   * (none)
 
Minor Changes
   * Allow loading SP2 files from Live Image View without configured analyzer(#6677)
   * Power Conditioning removed in UXC1000 MF (#6658)
   * Configuration of Focus Spin Voltage (#6746)
 
Bugfixes
   * Display water temperature in degree in UXC1000 (#6750)
   * Switching to single window layouts does not embed dock widgets correctly (#6726)
   * Timeout when switching-off Focus Spin Detector (#6725)
   * Deadlock when switching from Experiment to Live-Mode (#6719)
   * Detector Calibration View does not fit to screen (#6698)
   * Slider range does not apply to Min/Max values of current mode (#6620)
   * Deadlock and Crash after experiment (#6784, #6791)
   * Spectrum tooltip fixed (#6776)
 
 
=================================================
Version 4.37.0
=================================================

Major Changes
   * (none)
 
Minor Changes
   * Shirley-Background calculation is performed iteratively (#6425)
 
Bugfixes
   * Validation of logical voltages does not take into account the lens mode (#6674)
   * Output parameter of operation are not always set after renaming an operation (#6669)
   * Quantification serialization fails due to invalid mapping (#6666)
   * Endless layout updates in Data Browser (#6659)
   * Experiment Editor shows error message when aborting while turning devices off (#6651)
   * Drag & Drop might fail due to tree-locks (#6647)
   * Missing error message when voltages cannot be ramped (#6600)
   * Deadlock when activating experiment commands (#5760)
   * Counter set integration time shows error in ARMIN device (#6717)
   * Serial communication with NSRRC beamline (#6708)
   * (4.37.2) Deadlock when validating second scan in RemoteIn (#6791)
   * (4.37.2) Improved data integrity for SLE export (#6712)
 
=================================================
Version 4.36.0
=================================================

Major Changes
   * (none)
 
Minor Changes
   * Add support for Phoibos 150 SAL (#6596)
   * Add support for FG 500-A (with FG22/35) (#6500)
   * Configure which USB Pixelfly to connect to (#6372)
   * Export operation results regarding different axes units (#6496)
 
Bugfixes
   * XPS Ranges Databases Consistency (#6471)
   * Profiling data display in Image Viewer (#6539)
   * Changing number of scans during measurements might abort acquisition (#6618)
   * Processing time estimation when node gets deactviated (#6594)
   * Wrong excitation energy for Cr K Alpha anodes (#6553)
   * Missing Add-Buttons for duplicated experiments (#6641)
 
 
=================================================
Version 4.35
=================================================

Major Changes
 * Acquiring more scans after initial measurement is finished (#2087)
 
Minor Changes
 * IGOR export optimized for large data (#6517)
 * Selectable slider ranges in Analyzer device (#6370)
 * Show operation results by axes settings in Data Browser (#3883)
 * (4.35.2) Integrate additional temperature sensor in LSH150 (#6591)
 
Bugfixes
 * Phoibos live aquisition timeout error (#6550)
 * Prodigy does not exit when Remote Control is running in second window (#6492)
 * Deadlock when autosave is activated (#6490)
 * Deadlock on ClearSpectrum in RemoteIn (#6477)
 * Mismatching number of sample points in RemoteIn (#6473)
 * Wrong column labels of external channels in XY Exporter (#6465)
 * Wrong cycle information in Controller Toolbar (#6458)
 * Crash when specsdevs is not reacting in Live Mode Ramping (#6455)
 * Protocolled parameters of analyzer command do not consider optional values (#6579)


=================================================
Version 4.34
=================================================

Major Changes
 * (none)
 
Minor Changes
 * Config Tool has more default axes configurations (#6267)
 * Flipped z-Profile Plot in Image Viewer (#6405)
 * ArminConfig Tool: Increase timeout for flash WRITE_PAGE (#6420)
 
Bugfixes
 * Vacuum Control: fatal error after SpecsDevs crash (#6421)
 * Quantification Operation does not write custom name (#6424)
 * (4.34.2) Could not start acquisition with PCO 1300 (#6566)
 * (4.34.2) Crash while taking a snapshot (#6536)
 * (4.34.2) Wrong axis values in Live Image (#6493)
 
 
=================================================
Version 4.33
=================================================

Major Changes
 * Allow multiple schedules per Experiment Editor (#6170)
 * Configurable devices status at end of experiment (#6252)
 * Added support for NAP LEEM stage control (#6076)
 
Minor Changes
 * Automatically show and hide Experiment Editor and Data Browser settings (#6166)
 * Added Pfeiffer TPR280 to predefined gauge types in VSC Gauge (#6288)
 * Support 3D waves IGOR export with two cycles (#6216)
 * Arrange experiment files in toolbox pages in Data Browser (#6168)
 * Improved acquisition time in Prodigy for multi-HSA systems (#6313)
 * Use VSC Gauge as external channel (#6091)
 
Bugfixes
 * Cannot delete or deactivate spectrum group without activated spectrum (#6290)
 * Crash when using unknown device in two live data views (#6386)
 * IQE 12/38 changes its state on connect and disconnect (#6304)
 * Images are not accumulated when using dwell time split in Prodigy (#6408)
 * Timeout error in Armin configuration tool (#6420)
 * Live Image View shows raw images in strange colors (#6318)
 * LEEM Analyzer wrong default HSA config file (#6302)
 * Setting voltage impacts other voltages from TCP remote interface (#6289)
 * SpecsDevs allocation error (#6259)
 * (4.33.2) No data provided from DLD Detector during acquisition (#6454)
 * (4.33.2) Wrong pressure range for Vacom Atmion in VSC Gauge (#6403)
 * (4.33.2) XY file exporter does not use input parameters (#6464)
 * (4.33.2) Loading Remote Out device configurations sometimes crashes Config Tool (#6450)
 * (4.33.2) Specsdevs crashes when connecting to unreachable TDC (#6456)
 
 
=================================================
Version 4.32
=================================================

Major Changes
 * Added support for Plasma Cleaner device (#5992)
 * Extend export functionalities in image views (#5744)
 
Minor Changes
 * VAMAS and XY export of selected groups (#4167)
 * Show VSC channels in VSC Valve device (#6221)
 * Keep certain dock widgets open on layout change (#6171)
 * Allow loading SLT files and user templates with unknown devices (#4483)
 * Improved time estimation and status message in ramping node (#6257)
 * Export channel scale within SP2 data in Live Image View (#6207)
 * Use Prodigy remote control to set HSA voltages without a detector (#6029)
 * Support saving spectrum as template (#6240)
 * Simplified spectrum creation (#6169)
 * Set number of non energy channels from TCP remote interface (#4064)
 * Hide AES and ISS spectrums in Plot View when binding energy is selected (#5951)
 * Enable auto-zoom in Plot View with double-click (#6161)
 * Improved histogram range editing (#6322)
 * Improved splitter behaviour with image operation results (#6208)
 
Bugfixes
 * Error transport in Prodigy (#6232)
 * Detector calibration produces unreasonable shifts (6326)
 * Inconsistent HSA configuration file name for spin detector (#6202)
 * Operation results are not stored during abort (#4571)
 * Could not write non-ASCII bytes to serial port (#6268)
 * Unable to save SLE file due to foreign key constraint failure (#6249)
 * SLE files are not stored correctly (#6248)
 * Corrupt scan data for snapshot with active channel summation (#6254)
 * Invalid additional window in Prodigy (#5937)
 * Wrong operation range for detector voltage scan (#6246)
 * Unable to choose 4th device in Manipulator joystick control (#6245)
 * Could not load configuration in VSC valve (#6244)
 * Wrong retardation ratio is shown in printout for fixed retardation ratio spectrums (#6239)
 * Wrong pressure for MKS gauges (#6214)
 * Excitation energy is not updated for selected spectrum from Periodic Library (#5989)
 * Crash when renaming node in Prodigy (#6206)
 * Copy to clipboard does not contain image range marker in Image View (#6219)
 * Cannot delete or deactivate spectrum group without activated spectrum (#6290)
 * Could not start acquisition after changing detector voltages without applying in analyzer command (#6300)
 * Errors on open and close are being suppressed in VSC valve (#6309)
 * Profiling of analyzer voltages does not work (#6307)
 * Prodigy sometimes hangs during measurement (#6312)
 * Switch all devices off turns off vacuum devices (#6327)
 
 
=================================================
Version 4.31
=================================================

Major Changes
 * Added support for deflector control in analyzer device (#6068)
 
Minor Changes
 * Hide status notification on Windows taskbar (#6154)
 * Improved axis text in time based logging (#2876)
 * Improved MCU8 device control (#6196)
 * Reference movement only for specified axes in manipulator device (#6184)
 * Distinguish between set and read values for HSA voltages in Live Data View (#5960)
 
Bugfixes
 * Plot alignment in printouts broken (#6071)
 * Connection failed in LEEM analyzer device (#6124)
 * Wrong usage of dwell time split in Pixelfly USB (#6159)
 * Detector calibration yields incorrect calibration error(#6085)
 * Interrupt is triggered by connecting in VSC Gauge (#6007)
 * Configuration of external operation is not serialized (#5473)
 * MCD calibration does not always yield a reasonable result (#5961)
 * Snapshots show wrong tick labels along x-axis of image views (#6126)
 * Standard channels are sometimes not shown in analyzer device (#6133)
 * Incompatibility between HSA configuration and Calib2D files (#6135, #341)
 * Storage of operation results slows down with increasing number of cycles (#5681)
 * Cannot move in manipulator device control after STO activation (#6203)
 * Logical voltage ranges are not validate before the acquisition is started (#5642)
 * Selection in experiment editor triggers unintended auto-zoom in plot views (#6161)
 * Profile plots of image views do not take projection method into account (#6143)
 * Current positions are not updated in manipulator device when leaving limit switches (#6150)

 
=================================================
Version 4.30
=================================================

Major Changes
 * Visualization of 4D data (#5562)
 * Added export to native IGOR 3D waves (#6012)
 * Include vacuum devices in Prodigy for logging (#5952)
 * Simplify configuration of VSC Devices (#5721)
 * Extended Prodigy options (#6081)
 
Minor Changes
 * Improved name editing in data browser and experiment editor (#5340)
 * Faster preset activation during scans in XRC125 (#6009)
 * Improved anode motor safety in XRC125 (#6057)
 * Faster acquisitions with Pixelfly USB (#5077)
 * Faster acquisitions with DLDs (#6072, #6090)
 * Improved transmission user interface (#4248)
 * Live Data View can handle dynamic device parameters (#4998)
 
Bugfixes
 * Unexpected reactions when leaving limit switches with SE Drives (#6086)
 * Aborts prodigy start when parameter not available in Live Parameter View (#6069)
 * External channels are initially red but should be auto-colored (#5890)
 * Duplicate "+" page in context with maximization in dock widgets (#6098)
 * Cannot restore layout "Recent" (#6097)
 * Cannot Connect in manipulator device control while STO is Active (#6079)
 * Pixelfly USB using dwell time split (#6159)
 * Red selection not movable in histogramm (#6160)
 * Fast activate does not work in standby in XRC125 (#6165)
 * Wrong limit switches detection when reference switch is active in SE Drives (#6183)
 * Timeout error during connection with 2D detector is not always Propagate in Prodigy (#6182)
 * HSA3500DiagTool fails on new HSA3500PLUS Modules with AVR uController (#4330)
 * (4.30.2) Excitation energy is not stored when saving configuration with non mono anode in XRC1000M (#6193)
 * (4.30.2) Sealing gas does not work in Pfeiffer HiPace(#6197)
 * (4.30.2) Wrong conversion from voltage to pressure in MKS Gaugee (#6124)
 * (4.30.3) Lensmodes in calib2d file for Phoibos NAP R3 (#341)
 * (4.30.3) Enable 4th Joystick device for manipulator control (#6245)
 * (4.30.4) Operation range for detector voltage scan in data browser (#6246)
 * (4.30.4) Second window can be opened more than once in Prodigy (#5937)
 * (4.30.4) Data history view always uses the same y-scale for constant y-values (#6253)
 * (4.30.4) Corrupt scan data for SFAT spectrums when channel summation is activated (#6254)
 * (4.30.4) Invalid image transformation parameters when using PCO PixelFly USB (#6258)
 * (4.30.4) Unable to open files with ramping node (#6256)

 
(Older information can be found in the RELEASE-SpecsLab Prodigy.txt file of the zip file.)



pix
SpecsLab Prodigy
Product Brochure
SpecsLab Prodigy


pix
pix
© SPECS GmbH all rights reserved
    PRINT PAGE
  Sitemap   Terms   Legal Details 
pix
pix